Specification clause · NCC 2022 Volume One

S6C6 Walls generally

Specification 6 Structural tests for lightweight construction · NCC 2019: Spec C1.8: 3.4

Open S6C6 on NCC Online ↗

An external and internal wall of lightweight construction that is required to be fire-resisting, other than one covered by S6C3, S6C4 or S6C5, must be subjected to the following tests and must fulfil the following criteria:

The materials tests of S6C10(a) and the criteria of S6C11(a).

A static test by the imposition of a uniformly distributed load of 0.25 kPa (or its equivalent) in accordance with S6C10(b) and the damage and deflection criteria of S6C11(b) and (c) respectively.

A dynamic test by fall of the impact bag through a height of 100 mm in accordance with S6C10(c) and the damage and deflection criteria of S6C11(b) and (d) respectively.

The surface indentation test of S6C10(d) and the surface indentation criterion of S6C11(e).

Changed in NCC 2025 (minor wording). See NCC 2025 Volume One S6C6, or show what changed.

An external wall and internal wall of lightweight construction that is required to … test of S6C10(d) and the surface indentation criterion of S6C11(e).

Removed words are struck through; added words are highlighted. Comparison of the text only.

Clauses referred to

Defined terms used