South Australia variation · NCC 2022 Volume One
SA D3D23 Fixed platforms, walkways, stairways and ladders
Part D3 Construction of exits · varies D3D23 Fixed platforms, walkways, stairways and ladders
Delete clause D3D23 and insert SA D3D23 as follows:
A fixed platform, walkway, stairway, ladder and any going and riser, landing, handrail or barrier attached thereto may comply with AS 1657 in lieu of D3D14, D3D15, D3D17, D3D18, D3D19, D3D20, D3D21 and D3D22 if it only serves—
machinery rooms, boiler houses, lift-machine rooms, plant-rooms, and the like; or
non-habitable rooms, such as attics, storerooms and the like that are not used on a frequent or daily basis in the internal parts of a sole-occupancy unit in a Class 2 building or Class 4 part of a building; or
areas within a farm building.
Not in NCC 2025. No SA D3D23 in NCC 2025 Volume One.