Deemed-to-Satisfy Provision · NCC 2022 Volume Three

B2D6 Temperature control devices

Part B2 Heated water services · NCC 2019: B2.6, NSW B2.6(2)(d), Application 1 and Exemption 1, TAS B2.6(d)

Open B2D6 on NCC Online ↗
Varied in NSW, TAS, VIC. Check the variation for your state.

(1) A temperature control device used to deliver heated water in accordance with B2D5(a) must be a—

thermostatic mixing valve; or

thermostatically controlled tap.

(2) A temperature control device used to deliver heated water in accordance with B2D5(b) must be a—

thermostatic mixing valve; or

thermostatically controlled tap; or

tempering valve; or

temperature limited water heater.

(3) The required maximum delivery temperature must be achieved in accordance with AS/NZS 3500.4.

Applications

B2D6 applies to all heated water installations intended for personal hygiene.

Same wording in NCC 2025 Volume Three. See NCC 2025 Volume Three B2D6.

State and territory variations all clauses side by side →

Clauses referred to

Defined terms used