NCC 2025 Volume Three
Part B3 Non-drinking water services
16 clauses · Open on NCC Online ↗
- B3O1 ObjectiveThe Objective of this Part is to— safeguard people from illness, injury or loss (including loss of amenity) due to the failure of a non-drinking…
- B3F1 Non-drinking water supplySanitary fixtures, sanitary appliances and supply outlets provided with non-drinking water must be adequate.
- B3F2 Non-drinking water installationsNon-drinking water must be supplied through plumbing installations in a way that avoids the likelihood of inadvertent contamination of any drinking…
- B3P1 Non-drinking water supplyA non-drinking water service must not have a cross-connection with a drinking water service.
- B3P2 IdentificationPipes, outlets, fittings, storage and holding tanks that are part of a non-drinking water service must be clearly identified. (2) A non-drinking…
- B3P3 VelocityWater velocity within non-drinking water service pipework must not exceed 3 m/s for no less than 99% of the time that water is required during the…
- B3P4 AccessAccess must be provided to components of a non-drinking water service that require maintenance or replacement, including mechanical devices and…
- B3P5 IsolationMeans of isolation must be provided to a non-drinking water service and components that require testing, maintenance and replacement including…
- B3P6 PressureThe points of discharge for a non-drinking water service must— have— a working pressure of not less than 50 kPa; and a static pressure within the…
- B3P7 Uncontrolled dischargeAny failure or uncontrolled discharge from a non-drinking water service must be avoided.
- B3P8 Water efficiency NSWWhere a non-drinking water service is used for flushing of toilets or urinals, efficient use of non-drinking water must be achieved by—…
- B3D1 Deemed-to-Satisfy ProvisionsWhere a Deemed-to-Satisfy Solution is proposed, Performance Requirements B3P1 to B3P8 are satisfied by complying with B3D2 and B3D5. (2) Where a…
- B3D2 Distribution of non-drinking waterA non-drinking water service must not be connected to any outlet that supplies water for— human consumption; or food preparation; or food utensil…
- B3D3 General requirements NSW VICA non-drinking water service must be in accordance with AS/NZS 3500.1.
- B3D4 Bushfire prone areasA non-drinking water service in designated bushfire prone areas must be in accordance with AS 3959.
- B3D5 Water efficiency NSWCisterns or flushing devices for water closets must— have a dual flushing mechanism; and be a minimum 3 Star WELS rating, discharging not more than…