NCC 2025 Volume Two
Part H3 Fire safety
17 clauses · Open on NCC Online ↗
- H3O1 ObjectiveThe Objective is to— safeguard the occupants from illness or injury by alerting them of a fire in the building so that they may safely evacuate; and…
- H3F1 Protection from the spread of fireA Class 1 building is to be protected from the spread of fire.
- H3F2 Fire detection and early warningA Class 1 building is to be provided with safeguards so that occupants are warned of a fire in the building so that they may safely evacuate.
- H3P1 Spread of fire SAA Class 1 building must be protected from the spread of fire such that the probability of a building not being able to withstand the design heat…
- H3P2 Automatic warning for occupantsIn a Class 1 building, occupants must be provided with automatic warning on the detection of smoke with an efficacy greater than 0.95 and a…
- H3V1 Avoidance of spread of fire between buildings on one allotmentCompliance with H3P1(1)(a) to avoid the spread of fire between buildings on the same allotment is verified when— the external walls and any openings…
- H3V2 Avoidance of spread of fire from allotment boundaryCompliance with H3P1(1)(b) to avoid the spread of fire from an allotment boundary is verified when— the external walls and any openings in the…
- Table H3V3 Heat flux (adjoining allotment)Column 1 (Location) | Column 2 (Heat flux [kW/m2]) On boundary | 80 1 m from boundary | 40 3 m from boundary | 20 6 m from boundary | 10
- H3V3 Avoidance of spread of fire between buildings on adjoining allotmentsCompliance with H3P1(2) to avoid the spread of fire between buildings on adjoining allotments is verified when it is calculated that— a building…
- Table H3V4 Heat flux (same allotment)Column 1 (Location) | Column 2 (Heat flux [kW/m2]) 0 m | 80 2 m | 40 6 m | 20 12 m | 10
- H3V4 Avoidance of spread of fire between Class 2-9 buildingsCompliance with H3P1(2) to avoid a Class 10a building increasing the risk of fire spread between Class 2-9 buildings is verified when it is…
- H3D1 Deemed-to-Satisfy ProvisionsWhere a Deemed-to-Satisfy Solution is proposed, Performance Requirements H3P1 and H3P2 are satisfied by complying with H3D2 to H3D6. (2) Where a…
- H3D2 Fire hazard properties and non-combustible building elements NSWThe following materials, though combustible or containing combustible fibres, may be used wherever a non-combustible material is required:…
- H3D3 Fire separation of external wallsCompliance with Part 9.2 of the ABCB Housing Provisions satisfies Performance Requirement H3P1 for fire separation of external walls.
- H3D4 Fire protection of separating walls and floorsCompliance with Part 9.3 of the ABCB Housing Provisions satisfies Performance Requirement H3P1 for fire protection of separating walls and floors.
- H3D5 Fire separation of garage-top-dwellings NSWCompliance with Part 9.4 of the ABCB Housing Provisions satisfies Performance Requirement H3P1 for fire separation of garage-top dwellings.
- H3D6 Smoke alarms and evacuation lightingCompliance with Part 9.5 of the ABCB Housing Provisions satisfies Performance Requirement H3P2 for smoke alarms and evacuation lighting. (2) For the…