Deemed-to-Satisfy Provision · NCC 2025 Volume One

D3D18 Height of barriers

Part D3 Construction of exits · NCC 2019: Table D2.16a

Open D3D18 on NCC Online ↗
Varied in NSW. Check the variation for your state.

(1) The height of a barrier required by D3D17 must be not less than the following:

For stairways or ramps with a gradient of 1:20 or steeper — 865 mm.

For landings to a stair or ramp where the barrier is provided along the inside edge of the landing and does not exceed 500 mm in length — 865 mm.

In front of fixed seating on a mezzanine or balcony within an auditorium in a Class 9b building, where the horizontal projection extends not less than 1 m outwards from the top of the barrier — 700 mm.

For all other locations — 1 m.

(2) For a barrier provided under (1) —

barrier heights are measured vertically from the surface beneath, except that for stairways the height must be measured above the nosing line of the stair treads; and

a transition zone may be incorporated where the barrier height changes from 865 mm on a stair flight or ramp to 1 m at a landing or floor.

Same wording in NCC 2022 Volume One. See NCC 2022 Volume One D3D18.
Can't meet D3D18? A Performance Solution must meet the Performance Requirements it satisfies: D1P1, D1P2, D1P3, D1P4, D1P5, D1P6, D1P8, D1P10, D1P9. Start a Performance Solution →

State and territory variations all clauses side by side →

Clauses referred to

Defined terms used