J3D6 * * * * *
Part J3 Elemental provisions for a Class 4 part of a building · NCC 2019: J0.5
This clause has deliberately been left blank.
Changed since NCC 2022. See NCC 2022 Volume One J3D6, or show what changed.
(1) A metal-framed wall that forms part of the building envelope must have a thermal break, consisting of a material with an R-Value of not less than R0.2, installed at all points of contact between the external cladding and the metal frame if the wall — does not have a wall lining or This clause has a wall lining that is fixed directly to the same metal frame; and is clad with weatherboards, fibre-cement or the like, or metal sheeting fixed to a metal frame. (2) The requirements of (1) do not apply to walls constructed using insulated sandwich panels. deliberately been left blank.