Northern Territory variation · NCC 2025 Volume One

NT F4D4 Facilities in Class 3 to 9 buildings

NT Part F4 Sanitary and other facilities · varies F4D4 Facilities in Class 3 to 9 buildings

Open on NCC Online ↗

Delete clause F4D4 and insert NT F4D4 as follows:

(1) Except where permitted by (3), (4), (7), F4D5(a), F4D5(b) and F4D12(1), separate sanitary facilities for males and females must be provided for Class 3, 5, 6, 7, 8 or 9 buildings in accordance with Tables F4D4a, F4D4b, F4D4c, F4D4d, F4D4e, F4D4f, F4D4g, F4D4h, F4D4i, F4D4j, F4D4k and F4D4l, as appropriate.

(2) In Tables F4D4a, F4D4b, F4D4c, F4D4d, F4D4e, F4D4f, F4D4g, F4D4h, F4D4i, F4D4j, F4D4k and F4D4l l—

‘Number’ means the number of facilities required; and

‘>’ means greater than; and

a hyphen means no data (refer to the row above for the highest value applicable); and

‘N/A’ means not applicable; and

a reference to—

‘employees’ includes owners and managers using the building; and

‘add 1 per 100 or 150, 250, 500, etc.’ includes any part thereof of that number.

(3) If not more than 10 people are employed, a unisex facility may be provided instead of separate facilities for each sex.

(4) If the majority of employees are of one sex, not more than 2 employees of the other sex may share toilet facilities if the facilities are separated by means of walls, partitions and doors to afford privacy.

(5) Employees and the public may share the same facilities in a Class 6 and 9b building (other than a school or early childhood centre) provided the number of facilities provided is not less than the total number of facilities required for employees plus those required for the public.

(6) Separate sanitary facilities for males and females need not be provided for patients in a ward area of a Class 9a building.

(7) A Class 9a health-care building must be provided with

One kitchen or other adequate facility for the preparation and cooking or reheating of food including a kitchen sink and washbasin; and

Laundry facilities for the cleaning and drying of linen and clothing or adequate facilities for holding and dispatch or treatment of soiled linen and clothing, sanitary products and the like and the receipt of clean linen; and

On shower for each 8 patients or part thereof; and

One island-type plunge bath in each storey containing a ward area.

(8) A Class 9b early childhood centre must be provided with—

A kitchen or food preparation area with a kitchen sink, separate hand washing facilities, space for a refrigerator and space for cooking facilities, with

the facilities protected by a door or gate with child proof latches to prevent unsupervised access to the facilities by children younger than 5 years old; and

the ability to facilitate supervision of children from the facilities if the early childhood centre accommodates children younger than 2 years old.

New in NCC 2025. No NT F4D4 in NCC 2022 Volume One; it may have moved or been renumbered.