NCC 2025 Volume One
Northern Territory variations
36 NT variations to NCC 2025 Volume One: clauses replaced, added or deleted in Northern Territory. Search with NT variations.
- NT B1D4 Determination of structural resistance of materials and forms of constructionDelete clause B1D4 and insert NT B1D4 as follows: The structural resistance of materials and forms of construction must be determined in accordance…
- NT E1D10 Where sprinklers are required: Class 9a and 9c buildingsDelete clause E1D10 and insert NT E1D10 as follows: (1) In a Class 9a health-care building used as a residential care building, sprinklers are…
- NT F4D4 Facilities in Class 3 to 9 buildingsDelete clause F4D4 and insert NT F4D4 as follows: (1) Except where permitted by (3), (4), (7), F4D5(a), F4D5(b) and F4D12(1), separate sanitary…
- NT F7D1 Deemed-to-Satisfy ProvisionsInsert NT clause F7D1 in clause F7D1 as follows: (1) Where a Deemed-to-Satisfy Solution is proposed, Performance Requirements F7P1 to F7P4 are…
- NT F7D2 Application of PartInsert NT clause F7D2 in clause F7D2 as follows: The Deemed-to-Satisfy Provisions of this Part apply to Class 2 and 3 buildings and Class 9c aged…
- NT F7D3 Weighted sound reduction index: interpretationInsert NT clause F7D3 in clause F7D3 as follows: A form of construction required to have a certain weighted sound reduction index (RW) must— have…
- NT F7D4 Sound insulation of floors between unitsInsert NT clause F7D4 in clause F7D4 as follows: A floor separating sole-occupancy units must have an RW not less than 45.
- NT F7D5 Sound insulation of walls between unitsInsert NT clause F7D5 in clause F7D5 as follows: A wall must have an RW not less than 45 if it separates— sole-occupancy units; or a sole-occupancy…
- NT F7D6 Walls between a bathroom, sanitary compartment, laundry or kitchen and a habitable room in adjoining unitInsert NT clause F7D6 in clause F7D6 as follows: (1) Except for a Class 9c building, a wall separating a bathroom, sanitary compartment, laundry or…
- NT F7D7 Soil and waste pipes to be separatedInsert NT clause F7D7 in clause F7D7 as follows: If a soil or waste pipe, including a pipe that is embedded in or passes through a floor, serves or…
- NT F7D8 Isolation of pumpsInsert NT clause F7D8 in clause F7D8 as follows: A flexible coupling must be used at the point of connection between the service pipes in a building…
- NT F7D9 Walls between a bedroom and kitchen or laundry in a Class 9c buildingInsert NT clause F7D9 in clause F7D9 as follows: In addition to NT F7D5, a wall separating a sole-occupancy unit in a Class 9c building from a…
- NT F7P1 Sound transmission through floorsInsert NT clause F7P1 in clause F7P1 as follows: Floors separating sole-occupancy units or a sole-occupancy unit from a plant room, lift shaft,…
- NT F7P2 Sound transmission through wallsInsert NT clause F7P2 in clause F7P2 as follows: Walls separating— sole-occupancy units; or a sole-occupancy unit from a plant room, lift shaft,…
- NT F7P3 Sound transmission through wall and floor penetrationsInsert NT clause F7P3 in clause F7P3 as follows: The required sound insulation of floors and walls must not be compromised by the incorporation or…
- NT F7P4 Sound transmission through walls in residential care buildingsInsert NT clause F7P4 in clause F7P4 as follows: (1) Walls separating— sole-occupancy units; or a sole-occupancy unit from a kitchen, bathroom,…
- NT G1D2 Swimming poolsThis clause has deliberately been left blank. Barriers and fences for swimming pools are regulated by the Northern Territory of Australia Swimming…
- NT G1D5 Swimming pool drainageThis clause has deliberately been left blank.
- NT G1P1 Swimming pool drainageThis clause has deliberately been left blank.
- NT G1P2 Swimming pool access and water recirculation systemsDelete clause G1P2 and insert NT G1P2 as follows: A swimming pool water recirculation system must incorporate safety measures to avoid entrapment…
- NT Part J1 Energy efficiency performance requirementsThis Part has deliberately been left blank. For a Class 2 building and Class 4 part of a building, Section J is replaced with Section J of BCA 2009…
- NT Part J2 Energy efficiencyThis Part has deliberately been left blank. For a Class 2 building and Class 4 part of a building, Section J is replaced with Section J of BCA 2009…
- NT Part J3 Elemental provisions for a Class 4 part of a buildingThis Part has deliberately been left blank. For a Class 2 building and Class 4 part of a building, Section J is replaced with Section J of BCA 2009…
- NT Part J4 Building fabricThis Part has deliberately been left blank. For a Class 2 building and Class 4 part of a building, Section J is replaced with Section J of BCA 2009…
- NT Part J5 Building sealingThis Part has deliberately been left blank. For a Class 2 building and Class 4 part of a building, Section J is replaced with Section J of BCA 2009…
- NT Part J6 Air-conditioning and ventilationThis Part has deliberately been left blank. For a Class 2 building and Class 4 part of a building, Section J is replaced with Section J of BCA 2009…
- NT Part J7 Artificial lighting and powerThis Part has deliberately been left blank. For a Class 2 building and Class 4 part of a building, Section J is replaced with Section J of BCA 2009…
- NT Part J8 Heated water supply and swimming pool and spa pool plantThis Part has deliberately been left blank. For a Class 2 building and Class 4 part of a building, Section J is replaced with Section J of BCA 2009…
- NT Part J9 Energy monitoring and on-site distributed energy resourcesThis Part has deliberately been left blank. For a Class 2 building and Class 4 part of a building, Section J is replaced with Section J of BCA 2009…
- NT S4C3 Strengthened areaInsert NT clause S4C3 in clause S4C3 as follows: (1) Where a residential building of Class 1b, 2, 3, 9a or 9c, in Region B2 or C as defined by…
- NT S28C1 ScopeDelete clause S28C1 and insert NT S28C1 as follows: This Specification lists the weighted sound reduction index RW for some common forms of…
- NT S28C2 Construction deemed-to-satisfyDelete clause S28C2 and insert NT S28C2 as follows: The forms of construction listed in NT S28C3 are considered to have the RW stated in that clause…
- NT S28C3 RW applicable to constructionDelete clause S28C3 and insert NT S28C3 as follows: (1) Construction in accordance with the following has an RW of not less than 45: Walls — clay…
- NT S29C1 ScopeDelete clause S29C1 and insert NT S29C1 as follows: This Specification describes a method of test to determine the comparative resistance of walls…
- NT S29C2 Construction to be testedDelete clause S29C2 and insert NT S29C2 as follows: (1) The test is conducted on a specimen of prototype wall construction and on a specimen of one…
- NT S29C3 MethodDelete clause S29C3 and insert NT S29C3 as follows: (1) The wall constructions to be compared must be tested in accordance with AS 1191. (2) A…