NT F7D9 Walls between a bedroom and kitchen or laundry in a Class 9c building
NT Part F7 Sound transmission and insulation
Insert NT clause F7D9 in clause F7D9 as follows:
In addition to NT F7D5, a wall separating a sole-occupancy unit in a Class 9c building from a kitchen or laundry must—
for other than masonry, be two or more separate leaves without rigid mechanical connection except at their periphery; or
be identical with a prototype that is no less resistant to the transmission of impact sound when tested in accordance with NT Specification 29 than a wall listed in NT S28C3.