Housing Provisions clause · ABCB Housing Provisions 2022
6.3.2 Structural steel members
Part 6.3 Structural steel members · NCC 2019: 3.4.4.2
(1) Structural steel members may be used as follows:
Bearers supporting a timber floor or non-loadbearing stud wall — in accordance with 6.3.3.
Strutting beams supporting roof and ceiling loads — in accordance with 6.3.4.
Lintels supporting roof, ceiling, frame and timber floor — in accordance with 6.3.5.
Columns — in accordance with 6.3.6.
(2) Structural steel members in (1)(a), (b) and (c) must have a minimum nominal yield strength of 250 MPa.
(3) The yield strength of structural steel members in (1)(d) is nominated in 6.3.6.
(4) Structural steel members described in this Part must be protected against corrosion in accordance with 6.3.9.
Same wording in ABCB Housing Provisions 2025. See ABCB Housing Provisions 2025 6.3.2.