F1D7 Damp-proofing of floors on the ground
Part F1 Surface water management, rising damp and external waterproofing · NCC 2019: SA F1.10, F1.10
(1) If a floor of a room is laid on the ground or on fill, moisture from the ground must be prevented from reaching the upper surface of the floor and adjacent walls by the insertion of a vapour barrier in accordance with AS 2870.
(2) The requirements of (1) do not apply where—
weatherproofing is not required; or
the floor is the base of a stair, lift or similar shaft which is adequately drained by gravitation or mechanical means.
Changed in NCC 2025. See NCC 2025 Volume One F1D7, or show what changed.
(1) If a floor A roof, balcony, podium or similar horizontal surface part of a room is laid on the ground or on fill, moisture from the ground building must be prevented from reaching the upper surface provided with a waterproofing membrane — consisting of the floor materials complying with AS 4654.1; and adjacent walls by the insertion of a vapour barrier designed and installed in accordance with AS 2870. 4654.2. (2) The requirements of Where a membrane required by (1) do not apply where — weatherproofing is not required; or the floor is the base of applied to a stair, lift concrete roof, balcony, podium or similar shaft which is adequately drained by gravitation or mechanical means. horizontal surface, the membrane must be installed directly on a structural substrate complying with F1D5.
Removed words are struck through; added words are highlighted. Comparison of the text only.