Deemed-to-Satisfy Provision · NCC 2025 Volume One
J7D5 Interior decorative and display lighting
Part J7 Artificial lighting and power · NCC 2019: J6.4
(1) Interior decorative and display lighting, such as for a foyer mural or art display, must be controlled—
separately from other artificial lighting; and
by a manual switch for each area other than when the operating times of the displays are the same in a number of areas such as in a museum, art gallery or the like, in which case they may be combined; and
by a time switch in accordance with Specification 40 where the display lighting exceeds 1 kW.
(2) Window display lighting must be controlled separately from other display lighting.
Same wording in NCC 2022 Volume One. See NCC 2022 Volume One J7D5.
Can't meet J7D5? A Performance Solution must meet the Performance Requirements it satisfies: J1P1, J1P2, J1P3, J1P4. Start a Performance Solution →