South Australia variation · NCC 2025 Volume One

SA F4D7 Accessible unisex showers

SA Part F4 Sanitary and other facilities · varies F4D7 Accessible unisex showers

Open on NCC Online ↗

Delete subclause F4D7(1) and insert SA F4D7(1) as follows:

(1) Where required by F4D5(b), the minimum number of accessible unisex showers for each Class of building is as follows:

For a Class 1b building—

not less than 1; and

where private accessible unisex showers are provided for every accessible bedroom, common accessible unisex showers need not be provided.

For a Class 2 building—

where showers are provided in common areas, not less than 1; and

in every sole-occupancy unit required by SA D4D2(4) to be accessible, not less than 1.

For Class 3 and 9c buildings—

in every accessible sole-occupancy unit provided with showers within the accessible sole-occupancy unit, not less than 1; and

1 for every 10 showers or part thereof provided in common areas.

For Class 5, 6, 7, 8 or 9 buildings, where F4D4 requires 1 or more showers, not less than 1 for every 10 showers or part thereof.

For a Class 10a building, where showers are provided, 1 for every 10 showers or part thereof.

Same wording in NCC 2022 Volume One. See NCC 2022 Volume One SA F4D7.