Table · NCC 2025 Volume One

Table J4D6b Minimum wall Total R-Value - Wall area 80% or more of wall-glazing construction area

Part J4 Building fabric

Open Table J4D6b on NCC Online ↗
Climate zoneClass 5, 6, 7, 8 or 9b building or a Class 9a building other than a ward areaClass 3 or 9c building or Class 9a ward area
13.04.0
21.01.0
32.22.4
42.01.9
51.01.0
61.21.0
72.22.2
83.63.6

Table for J4D6 Walls and glazing

Changed since NCC 2022. See NCC 2022 Volume One Table J4D6b, or show what changed.

Climate zone | Eastern aspect solar admittance Class 5, 6, 7, 8 or 9b building or a Class 9a building other than a ward area | Northern aspect solar admittance | Southern aspect solar admittance | Western aspect solar admittance Class 3 or 9c building or Class 9a ward area 1 | 0.12 3.0 | 0.12 | 0.12 | 0.12 4.0 2 | 0.13 1.0 | 0.13 | 0.13 | 0.13 1.0 3 | 0.16 2.2 | 0.16 | 0.16 | 0.16 2.4 4 | 0.13 2.0 | 0.13 | 0.13 | 0.13 1.9 5 | 0.13 1.0 | 0.13 | 0.13 | 0.13 1.0 6 | 0.13 1.2 | 0.13 | 0.13 | 0.13 1.0 7 | 0.13 2.2 | 0.13 | 0.13 | 0.13 2.2 8 | 0.2 3.6 | 0.2 | 0.42 | 0.36 3.6

Removed words are struck through; added words are highlighted. Comparison of the text only.

Defined terms used