NCC 2025 Volume One
Victoria variations
24 VIC variations to NCC 2025 Volume One: clauses replaced, added or deleted in Victoria. Search with VIC variations.
- VIC User group Facility type Design occupancy Number Children Closet pans 1 - 30 2 >30 Add 1 per 15 Washbasins 1 - 30 2 >30 Add 1 per 15 Note Urinals…
- VIC A2G2 Performance SolutionDelete clause A2G2 and insert VIC A2G2 as follows: (1) A Performance Solution is achieved by demonstrating— compliance with all relevant Performance…
- VIC A5G4 Evidence of suitability ─ Volume Three (PCA)Delete clause A5G4 and insert VIC A5G4 as follows: (1) Any product that is intended for use in contact with drinking water must comply with the…
- VIC B1D6 Construction of buildings in flood hazard areasDelete clause B1D6 and insert VIC B1D6 as follows: (1) A Class 2 or 3 building, Class 9a health-care building, Class 9c building or Class 4 part of…
- VIC C2D11 Fire hazard propertiesDelete subclause C2D11(3) and insert VIC C2D11(3) as follows: (3) The requirements of (1) do not apply to a material or assembly if it is— plaster,…
- VIC D2D1 Deemed-to-Satisfy ProvisionsDelete subclause D2D1(1) and insert VIC D2D1(1) as follows: (1) Where a Deemed-to-Satisfy Solution is proposed, Performance Requirements D1P1 to…
- VIC D2D9 Width of doorways in exits or paths of travel to exitsDelete clause D2D9 and insert VIC D2D9 as follows: (1) In a required exit or path of travel to an exit, the unobstructed width of a doorway must be…
- VIC D2D24 Doorways to a children’s roomInsert VIC clause D2D24 in clause D2D24 as follows: In an early childhood centre, a children’s room must— have a doorway providing direct access to…
- VIC D3D26 Operation of latchDelete subclause D3D26(1) and insert VIC D3D26(1) as follows: (1) A door in a required exit, forming part of a required exit or in the path of…
- VIC E1D6 Where sprinklers are required: Class 2 and 3 buildings other than residential care buildingsDelete clause E1D6 and insert VIC E1D6 as follows: (1) Sprinklers are required throughout— A shared accommodation building; and In a Class 2 or 3…
- VIC F4D1 Deemed-to-Satisfy ProvisionsDelete subclause F4D1(1) and insert VIC F4D1(1) as follows: (1) Where a Deemed-to-Satisfy Solution is proposed, Performance Requirements F4P1 to…
- VIC F4D2 Facilities in residential buildingsInsert VIC subclause F4D2(6) in clause F4D2 as follows: (6) In addition to (3) and (5), in a Class 3 and 9a residential aged care building and Class…
- VIC F4D4 Facilities in Class 3 to 9 buildingsDelete subclause F4D4(9) and insert VIC F4D4(9) as follows: (9) A Class 9b early childhood centre, other than a restricted children’s service, must…
- VIC F4D8 Construction of sanitary compartmentsDelete subclause F4D8(3) and insert VIC F4D8(3) as follows: (3) In an early childhood centre, other than a restricted children’s service, closet…
- VIC F4D13 First aid roomsInsert VIC clause F4D13 in clause F4D13 as follows: (1) If an assembly building or an open spectator stand accommodates more than 5000 spectators at…
- VIC F5D1 Deemed-to-Satisfy ProvisionsDelete clause F5D1 and insert VIC F5D1 as follows: Where a Deemed-to-Satisfy Solution is proposed, Performance Requirement VIC F5P1 is satisfied by…
- VIC F5D3 Class 3, 9a and 9c residential aged care buildings – size of roomsInsert VIC clause F5D3 in clause F5D3 as follows: In a residential aged care building or residential care building — each bedroom must have a floor…
- VIC F5P1 Room or space heightsDelete clause F5P1 and insert VIC F5P1 as follows: A habitable room or space must have sufficient size to enable the room or space to fulfil its…
- VIC F5V1 Room or space heightsDelete subclause F5V1(1) and insert VIC F5V1(1) as follows: (1) Compliance with VIC F5P1 is verified only in relation to the height of a habitable…
- VIC I4D1 Deemed-to-Satisfy ProvisionsDelete clause I4D1 and insert VIC I4D1 as follows: Performance Requirement VIC I4P1 is satisfied by complying with VIC I4D2.
- VIC I4D2 Electronic communication systemDelete clause I4D2 and insert VIC I4D2 as follows: A communication system must— contain a back-up power supply; and have a control that enables the…
- VIC I4P1 Communication systemsDelete clause I4P1 and insert VIC I4P1 as follows: An electronic communication system must be provided to enable residents and staff to summon…
- VIC S17C15 Balconies in Class 2, 3, 9a and 9c buildingInsert VIC clause S17C15 in clause S17C15 as follows: Covered balconies in Class 2, 3, 9a or 9c buildings must be sprinkler protected.
- VIC S18C5 Balconies in Class 2 and 3 buildingsInsert VIC clause S18C5 in clause S18C5 as follows: Covered balconies in Class 2 or 3 buildings must be sprinkler protected.