Definition · NCC 2022 Volume One
Fire compartment
Either—
the total space of a building; or
when referred to in—
the Performance Requirements — any part of a building separated from the remainder by barriers to fire such as walls and/or floors having an appropriate resistance to the spread of fire with any openings adequately protected; or
the Deemed-to-Satisfy Provisions — any part of a building separated from the remainder by walls and/or floors each having an FRL not less than that required for a fire wall for that type of construction and where all openings in the separating construction are protected in accordance with the Deemed-to-Satisfy Provisions of the relevant Part.
Used in
- A6G1 Determining a building classification
- S11C4 Doorways in smoke-proof walls
- C1P1 Structural stability during a fire
- C1P2 Spread of fire
- C1P9 Fire brigade access
- C2D10 Non-combustible building elements
- C2D14 Ancillary elements
- C3D3 General floor area and volume limitations
- C3D8 Separation by fire walls
- C4D2 Application of Part
- C4D6 Doorways in fire walls
- C4D8 Protection of doorways in horizontal exits
- D2D16 Horizontal exits
- D3D12 Fire-isolated passageways
- D3D24 Doorways and doors
- S21C4 Smoke reservoirs
- S21C6 Make-up air
- S21C7 Smoke exhaust system control
- E1P1 Fire hose reels
- E1P4 Automatic fire suppression systems