NCC 2022 Volume One
Part F7 Sound transmission and insulation
18 clauses · Open on NCC Online ↗
- F7O1 ObjectiveThe Objective of this Part is to safeguard occupants from illness or loss of amenity as a result of undue sound being transmitted— between adjoining…
- F7F1 Sound transmission and insulationA part of a building that separates— sole-occupancy units; or a sole-occupancy unit from a part of another classification in the building; or a…
- F7P1 Sound transmission through floors NTA floor separating sole-occupancy units or a sole-occupancy unit from a plant room, lift shaft, stairway, public corridor, public lobby, or the…
- F7P2 Sound transmission through walls NTA wall, including services and their penetrations, must minimise the transmission of sound such that— for airborne sound— a wall separating…
- F7P3 Sound transmission through floors in a residential care building NTA floor separating sole-occupancy units must minimise the transmission of airborne and impact generated sound such that the separating floor,…
- F7P4 Sound transmission through walls in a residential care building NTA wall separating sole-occupancy units, or a sole-occupancy unit from a kitchen, bathroom, sanitary compartment (not being an associated ensuite),…
- F7V1 Sound transmission through floors [F7P1]Compliance with F7P1 to avoid the transmission of airborne and impact generated sound through floors is verified when it is measured in-situ that…
- F7V2 Sound transmission through walls [F7P2(a)]Compliance with F7P2(a) to avoid the transmission of airborne sound through walls is verified when it is measured in-situ that— a wall separating…
- F7V3 Sound transmission through floors [F7P3]Compliance with F7P3 to avoid the transmission of airborne and impact generated sound through floors is verified when it is measured in-situ that…
- F7V4 Sound transmission through walls [F7P4(1)(a) and (2)]Compliance with F7P4(1)(a) and (2) to avoid the transmission of airborne sound through walls is verified when it is measured in-situ that— a wall…
- F7D1 Deemed-to-Satisfy Provisions NTWhere a Deemed-to-Satisfy Solution is proposed, Performance Requirements F7P1 to F7P4 are satisfied by complying with F7D2 to F7D8. (2) Where a…
- F7D2 Application of Part NTThe Deemed-to-Satisfy Provisions of this Part apply to Class 2 and 3 buildings and Class 9c buildings.
- F7D3 Determination of airborne sound insulation ratings NTA form of construction required to have an airborne sound insulation rating must— have the required value for weighted sound reduction index (Rw) or…
- F7D4 Determination of impact sound insulation ratings NTA floor in a building required to have an impact sound insulation rating must— have the required value for weighted normalised impact sound pressure…
- F7D5 Sound insulation rating of floors NTA floor in a Class 2 or 3 building must have an Rw + Ctr (airborne) not less than 50 and an Ln,w (impact) not more than 62 if it separates—…
- F7D6 Sound insulation rating of walls NTA wall in a Class 2 or 3 building must— have an Rw + Ctr (airborne) not less than 50, if it separates sole-occupancy units; and have an Rw…
- F7D7 Sound insulation rating of internal services NTIf a duct or soil, waste or water supply pipe, including a duct or pipe that is located in a wall or floor cavity, serves or passes through more…
- F7D8 Sound isolation of pumps NTA flexible coupling must be used at the point of connection between the service pipes in a building and any circulating or other pump.