J2D2 Application of Section J
Part J2 Energy efficiency · NCC 2019: J0.1
(1) For a Class 3 to 9 building, other than a Class 4 part of a building, Performance Requirement J1P1 is satisfied by complying with—
Part J4, for the building fabric; and
Part J5, for building sealing; and
Part J6, for air-conditioning and ventilation; and
Part J7, for artificial lighting and power; and
Part J8, for heated water supply and swimming pool and spa pool plant; and
J9D3, for facilities for energy monitoring; and
J9D5(2) to (4), for onsite renewable energy systems.
(2) For a Class 4 part of a building, Performance Requirement J1P2 is satisfied by complying with—
J3D3, using house energy rating software; or
the following—
J3D4, for ceiling fans; and
J3D5, J4D3(1) to (4), and Part J5, for general thermal construction; and
J3D7, for roofs; and
J3D8 and J3D11 to J3D13, or J3D9, for walls and glazing; and
J3D10, for floors.
(3) For a Class 4 part of a building, Performance Requirement J1P3 is satisfied by complying with—
for the net equivalent energy usage—
J3D14, for a Class 4 part of a building with a total floor area not greater than 500 m2; or
J3D15, using house energy rating software; and
Part J6, for air-conditioning and ventilation; and
Part J7, for artificial lighting and power.
(4) For a Class 3 to 9 building, Performance Requirement J1P4 is satisfied by complying with J9D4(1), J9D4(2) and J9D5(1).
Changed since NCC 2022. See NCC 2022 Volume One J2D2, or show what changed.
(1) For a Class 2 3 to 9 building, other than a sole-occupancy unit of a Class 2 building or a Class 4 part of a building, Performance Requirement J1P1 … and spa pool plant; and J9D3, for facilities for energy monitoring. monitoring; and J9D5(2) to (4), for onsite renewable energy systems. (2) For a sole-occupancy unit of a Class 2 building or a Class 4 part of a building, Performance Requirement J1P2 … or the following — J3D4, for ceiling fans; and J3D5, J3D6, J4D3, J4D7(3), J4D7(4) J4D3(1) to (4), and Part J5, for general thermal construction; and J3D7, for … walls and glazing; and J3D10, for floors. (3) For a sole-occupancy unit of a Class 2 building or a Class 4 part of a building, Performance Requirement J1P3 is satisfied by complying with — for the net equivalent energy usage — J3D14, for a sole-occupancy unit of a Class 2 building or a Class 4 part of a building with a total … J7, for artificial lighting and power. (4) For a Class 2 3 to 9 building, Performance Requirement J1P4 is satisfied by complying with J9D4 J9D4(1), J9D4(2) and J9D5. J9D5(1).
Removed words are struck through; added words are highlighted. Comparison of the text only.
State and territory variations all clauses side by side →
Clauses referred to
- J1P1 Operational energy use and greenhouse gas emissions
- J9D3 Facilities for energy monitoring
- J9D5 Facilities for solar photovoltaic and battery systems
- J1P2 Thermal performance of a Class 4 part of a building
- J3D3 Reducing heating and cooling loads of a Class 4 part of a building using house energy rating software
- J3D4 Ceiling fans in a Class 4 part of a building
- J3D5 Roof thermal breaks of a Class 4 part of a building
- J4D3 Thermal construction — general
- J3D7 Roofs and ceilings of a Class 4 part of a building
- J3D8 External walls of a Class 4 part of a building
- J3D11 External winter glazing of a Class 4 part of a building
- J3D13 Shading of a Class 4 part of a building
- J3D9 Wall-glazing construction of a Class 4 part of a building
- J3D10 Floors of a Class 4 part of a building
- J1P3 Energy usage of a Class 4 part of a building
- J3D14 Net equivalent energy usage of a Class 4 part of a building
- J3D15 Net equivalent energy usage for Class 4 part of building – home energy rating software
- J1P4 Renewable energy, energy storage and electric vehicle charging
- J9D4 Facilities for electric vehicle charging equipment