Definition · NCC 2025 Volume One
Fire-source feature
Any one or more of the following:
The far boundary of a road, river, lake or the like adjoining the allotment.
A side or rear boundary of the allotment.
An external wall of another building on the allotment which is not a Class 10 building.
The construction edge or perimeter of another building on the allotment which is not a Class 10 building and which has a use that constitutes a fire load.
Used in
- S5C2 Exposure to fire-source features
- Table S5C11a Type A construction: FRL of loadbearing parts of external walls
- Table S5C11b Type A construction: FRL of non-loadbearing parts of external walls
- S5C11 Type A fire-resisting construction — fire-resistance of building elements
- S5C18 Type A fire-resisting construction — open spectator stands and indoor sports stadiums: Concession
- S5C19 Type A fire-resisting construction — carparks
- Table S5C21a Type B construction: FRL of loadbearing parts of external walls
- Table S5C21b Type B construction: FRL of non-loadbearing parts of external walls
- Table S5C21c Type B construction: FRL of external columns not incorporated in an external wall
- S5C21 Type B fire-resisting construction — fire-resistance of building elements
- S5C22 Type B fire-resisting construction — carparks
- Table S5C24a Type C construction: FRL of parts of external walls
- Table S5C24b Type C construction: FRL of external columns not incorporated into an external wall
- S5C24 Type C fire-resisting construction — fire-resistance of building elements
- S5C25 Type C fire-resisting construction — carparks
- C4D3 Protection of openings in external walls
- D2D13 External stairways or ramps in lieu of fire-isolated exits